Home > Products > Network Power/Reserve Battery > Reserve Deep Cycle Battery > Reserve Deep Cycle current source Battery 12V150AH

Reserve Deep Cycle current source Battery 12V150AH

Payment Type:
L/C,T/T,D/P
Incoterm:
FOB,CFR,CIF
Min. Order:
100 Piece/Pieces
Transportation:
Ocean,Land
Share:
  • Product Description
Overview
Product Attributes

Model No.LFP12150D

Brandfirstpower

TypeLead-Acid Batteries

UsageUPS

Nominal Voltage12V

Discharge RateMedium Discharge Rate

ShapeSquare Battery

ElectrolyteAcid

InstallationFixed

RechargeableChargeable

High Rate Discharge BatterySealed Lead Acid Battery

Deep Cycle Battery FactoryBack-up Battery

UPS Battery FactorySolar Power Battery

Supply Ability & Additional Information

Packaging Carton & pallet packaging

Productivity2000, 000kvah/ Year

TransportationOcean,Land

Place of Originchina

Supply Ability2000, 000kvah/ Year

Certificateiso,UL,CE

Payment TypeL/C,T/T,D/P

IncotermFOB,CFR,CIF

Packaging & Delivery
Selling Units:
Piece/Pieces
Package Type:
Carton & pallet packaging

Reserve Deep Cycle Battery LFP12150D,capacity :12V150Ah batteries  is Sealed Lead Acid Battery. For using the sealed design, over-charging will dry out the electrolyte by driving the oxygen and hydrogen out of the battery, through the safety valves. Capacity is reduced and life is shortened If a battery is continually under-charged, a power robbing layer of sulfate will buildup on the plates. Battery performance is reduce, life is reduced.
can be used for just about every application, including: UPS Backup Systems, Alarm Systems, Fire Alarm Systems, Medical Equipment, Test Equipment, and much more. 


 Solar power


Specifications

Nominal Voltage

12 V

Capacity

(25)

10HR(10.8V)

150 Ah

5HR(10.5V)

130Ah

1HR(9.60V)

93Ah

Dimension

Length

485±2mm (19.09inch)

Width

172±2mm (6.77inch)

Height

240±2mm (9.45inch)

Total Height

T5: 242±2mm (9.53inch)

T11: 240±2mm (9.45inch)

Approx. Weight

44kg (97.0lbs)±4%

Terminal type

T5/T11

Internal resistance

(Fully charged, 25)

Approx. 3.5mΩ

Capacity affected by temperature (10HR)

40

102%

25

100%

0

85%

-15

65%

Self-discharge

(25)

3 month

Remaining Capacity: 91%

6 month

Remaining Capacity: 82%

12 month

Remaining Capacity: 65%

Nominal operating temperature

25±3(77℉±5)

Operating temperature range

Discharge

-15~50(5℉~122)

Charge

-10~50(14℉~122)

Storage

-20~50(-4℉~122)

Float charging voltage(25)

13.50 to 13.80V

Temperature compensation:

-18mV/

Cyclic charging voltage(25)

14.50 to 14.90V

Temperature compensation:

-30mV/

Maximum charging current

45A

Terminal material

Copper

Maximum discharge current

1200A(5 sec.)

Designed floating life(20)

15 years

◆ Absorbent glass mat technology;

◆ Recognized by UL & CE;

◆ ABS container.




 

Constant Current Discharge Characteristics (A, 25)

F.V/TIME

15min

30min

60min

2h

3h

4h

5h

6h

8h

10h

20h

9.60V

250

152

93.9

54.8

38.3

31.4

26.8

23.4

18.4

15.3

8.02

9.90V

244

148

92.5

54.5

38.0

31.2

26.6

23.3

18.3

15.2

8.00

10.2V

235

144

90.2

54.0

37.8

31.0

26.4

23.1

18.1

15.2

7.98

10.5V

227

140

88.4

53.2

37.5

30.8

26.3

23.0

18.0

15.1

7.93

10.8V

215

135

85.7

51.8

36.4

29.8

25.5

22.3

17.5

15.0

7.88

Constant Power Discharge Characteristics (Watt, 25)

F.V/TIME

15min

30min

60min

2h

3h

4h

5h

6h

8h

10h

20h

9.60V

2745

1700

1071

635

450

369

316

277

218

182

96.2

9.90V

2679

1666

1055

631

447

367

315

275

217

182

96.0

10.2V

2580

1615

1028

625

444

364

312

273

215

181

95.7

10.5V

2492

1576

1008

616

441

362

310

271

214

180

95.2

10.8V

2360

1518

977

600

428

351

301

263

207

179

94.5

Note: The above characteristics data can be obtained within three charge/discharge cycles.







International certifications:
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval

BS approval


FP Series Battery General Features

  • Nonspillable
  • Sealed and Maintenance-free Operation
  • High Quality and High Reliability
  • Exceptional Deep Discharge Recovery
  • Low Self-discharge
  • Long Service Life
  • Solid Copper Terminals
  • Tank-formed Plates
  • Computer-aided Design and Manufacturing
  • UL, CE, VdS Approved

Typical Applications

  • Telecommunication equipment
  • Electronic instruments
  • Fire alarm
  • Security devices
  • UPS power supply
  • Emergency lighting









Product Categories : Network Power/Reserve Battery > Reserve Deep Cycle Battery

Home > Products > Network Power/Reserve Battery > Reserve Deep Cycle Battery > Reserve Deep Cycle current source Battery 12V150AH
Email to this supplier
  • *Subject:
  • *To:
    Ms. SALES
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*

Related Products List

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send