Product Attributes

Model No.CFP2600

Brandfirstpower

TypeLead-Acid Batteries

UsageUPS

Nominal Voltage2V

Discharge RateMedium Discharge Rate

ShapeSquare Battery

ElectrolyteAcid

InstallationFixed

RechargeableChargeable

High Rate Discharge BatterySealed Lead Acid Battery

Deep Cycle Battery FactoryBack-up Battery

UPS Battery FactorySolar Power Battery

Supply Ability & Additional Information

Packaging Carton & pallet packaging

Productivity2000, 000kvah/ Year

TransportationOcean,Land

Place of Originchina

Supply Ability2000, 000kvah/ Year

Certificateiso,UL,CE

Payment TypeL/C,T/T,D/P

IncotermFOB,CFR,CIF

Packaging & Delivery
Selling Units:
Piece/Pieces
Package Type:
Carton & pallet packaging
2V Stationary Back-up Battery (CFP2600)
FirstPower Technology Co., Ltd. was set up as a manufacturer of rechargeable batteries in 1993.Be sure to keep sufficient space between batteries
for ventilation (where possible>10mm).
Be sure to install batteries in a cool and well
ventilated place.
The surrounding temperature must remain between20oC/
4oF to 50oC/122oF during storage.
Recharge the batteries at least every 6 months
during storage.
Be sure to consult FirstPower engineers any time you
are to use FirstPower VRLA batteries for your
products, or preparing your technical specifications
of FirstPower VRLA batteries.


Wind power

International certifications:
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval
BS approval
 CFP Series Battery General Features
Nonspillable
Sealed and Maintenance-free Operation
High Quality and High Reliability
Exceptional Deep Discharge Recovery
Low Self-discharge
Long Service Life
Solid Copper Terminals
Tank-formed Plates
Computer-aided Design and Manufacturing
UL, CE, VdS Approved
 
Typical Applications
Telecommunication equipment
Electronic instruments
Fire alarm
Security devices
UPS power supply
Emergency lighting
Specifications
Nominal Voltage 2 V
Capacity
(25ºC)
10HR(1.80V) 600 Ah
3HR(1.75V) 459Ah
1HR(1.75V) 339Ah
Dimension Length 302±2mm (11.89inch)
Width 175±2mm (6.89inch)
Height 330±2mm (12.99inch)
Total Height 367±2mm (14.45inch)
Approx. Weight 35kg (77.1lbs)±4%
Terminal type T10
Internal resistance
(Fully charged, 25ºC)
Approx. 0.45mΩ
Capacity affected by temperature (10HR) 40ºC 102%
25ºC 100%
0ºC 85%
-15ºC 65%
Self-discharge
(25ºC)
3 month Remaining Capacity: 91%
6 month Remaining Capacity: 82%
12 month Remaining Capacity: 65%
Nominal operating temperature 25ºC±3ºC(77ºF±5ºF)
Operating temperature range Discharge -15ºC~50ºC(5ºF~122ºF)
Charge -10ºC~50ºC(14ºF~122ºF)
Storage -20ºC~50ºC(-4ºF~122ºF)
Float charging voltage(25ºC) 2.25 to 2.30V
Temperature compensation:
-3mV/ºC
Cyclic charging voltage(25ºC) 2.42 to 2.48V
Temperature compensation:
-5mV/ºC
Maximum charging current 120A
Terminal material Copper
Maximum discharge current 4000A(5 sec.)
Designed floating life(20ºC) 20 years
Absorbent glass mat technology;
Recognized by UL & CE;
ABS container
 
Dimensions
Terminal: T10(M8)
Constant Current Discharge Characteristics (A, 25ºC)
F.V/TIME 15min 30min 60min 2h 3h 4h 5h 6h 8h 10h 20h 24h
1.60V 810 540 360 219 156 125 109 93.6 73.4 61.1 32.1 27.8
1.65V 791 529 355 218 155 125 108 93.1 73.0 61.0 32.0 27.7
1.70V 761 513 346 216 154 124 108 92.4 72.5 60.8 31.9 27.7
1.75V 735 501 339 213 153 123 107 91.8 72.0 60.4 31.7 27.5
1.80V 697 482 328 207 148 119 104 89.0 69.8 60.0 31.5 27.3
Constant Power Discharge Characteristics (Watt, 25ºC)
F.V/TIME 15min 30min 60min 2h 3h 4h 5h 6h 8h 10h 20h 24h
1.60V 1482 1010 684 423 306 246 215 184 146 122 64.1 55.9
1.65V 1447 990 674 421 304 244 213 183 145 121 64.0 55.8
1.70V 1393 959 657 417 302 243 212 182 144 121 63.8 55.6
1.75V 1346 936 644 411 300 241 210 181 143 120 63.4 55.3
1.80V 1275 902 624 400 291 234 204 175 139 119 63.0 54.9

Note: The above characteristics data can be obtained within three charge/discharge cycles.
 

Product Categories : Network Power/Reserve Battery > Standard Series Battery

Home > Products > Network Power/Reserve Battery > Standard Series Battery > Reserve Battery Sealed Telecom2V600Ah
Email to this supplier
  • *Subject:
  • *To:
    Ms. SALES
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*

Related Products List

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send