Home > Products > Network Power/Reserve Battery > High Rate Discharge Battery > Nimh Batteries Rechargeable

Nimh Batteries Rechargeable

Payment Type:
L/C,T/T,D/P
Incoterm:
FOB,CFR,CIF
Min. Order:
100 Piece/Pieces
Transportation:
Ocean,Land
Share:
  • Product Description
Overview
Product Attributes

Model No.LFP12134HR

Brandfirstpower

TypeLead-Acid Batteries

UsageUPS

Nominal Voltage12V

Discharge RateHigh Discharge Rate

ShapeSquare Battery

ElectrolyteAcid

InstallationFixed

RechargeableChargeable

High Rate Discharge BatterySealed Lead Acid Battery

UPS Battery FactorySolar Power Battery

Back Up Battery FactoryBack-up Battery

Supply Ability & Additional Information

Packaging Carton & pallet packaging

Productivity2000, 000kvah/ Year

TransportationOcean,Land

Place of Originchina

Supply Ability2000, 000kvah/ Year

Certificateiso,UL,CE

Payment TypeL/C,T/T,D/P

IncotermFOB,CFR,CIF

Packaging & Delivery
Selling Units:
Piece/Pieces
Package Type:
Carton & pallet packaging

 LFP12134HR is a typical High Rate Discharge Battery special designed for all kinds of high-power-ouput using application, 

It is a non-spillable and sealed and Maintenance-free operation battery, with high quality and high reliability, good deep discharge recovery, low self-discharge ,etc. The battery apply solid copper terminals,tank-formed plates computer-aided design and manufacturing

Main features as follow:
*
 Standby use.  Nimh Batteries Rechargeable

*  High rate discharge construction.

* ISO9001, 14001, OHSMS 18001 certified.

  UL, CE, VdS Approved. UL recognized components under UL 1989 (file number MH28204 ).

*With isolated seal, it can be put in horizontal way, vertical way and side way, its safety and functions totally will not be affected.

* With special formula to manufacture lead calcium alloy as well as automatic progresses, gassing will be less.
* Long life, low self-discharge rate and high reliability.
* It has safety, low resistance so recharge is easy and energy output is more remarkable.
* Container material could be frame retardant ABS or PP with ranking UL 94V-0 by model.
When it is used in safe surroundings, the battery is maintenance free, adding water is unnecessary and it can be recharged repeatedly.
*  Batteries are strictly tested by computer charge/discharge system.
*  Complies with IATA/ICAO Special Provision A67 for air transport.
*  Classified per MG Amendment 27 as a non-hazardous material for water transport.
* Recognized by DOT as "Dry charge" 49 CFR 171-189 for surface transport.






Specifications

Nominal Voltage

12 V

Number of cell

6 cells

Capacity(10HR, 25)

134 Ah

Capacity(15min.rate, 25)

475 Watts/cell

Dimension

Length

342±2mm (13.46inch)

Width

172±2mm (6.77inch)

Height

280±2mm (11.02inch)

Total Height

285±2mm (11.22inch)

Approx. Weight

43kg (94.8lbs)±4%

Terminal type

T11

Internal resistance

(Fully charged, 25)

Approx. 3.5mΩ

Capacity affected by temperature (20HR)

40

102%

25

100%

0

85%

-15

65%

Self-discharge

(25)

3 month

Remaining Capacity: 91%

6 month

Remaining Capacity: 82%

12 month

Remaining Capacity: 65%

Nominal operating temperature

25±3(77℉±5℉)

Operating temperature range

Discharge

-15~50(5℉~122)

Charge

-10~50(14℉~122)

Storage

-20~50(-4℉~122)

Float charging voltage(25)

13.50 to 13.80V

Temperature compensation:

-18mV/

Cyclic charging voltage(25)

14.50 to 14.90V

Temperature compensation:

-30mV/

Maximum charging current

40.2A

Terminal material

Copper

Maximum discharge current

1050A(5 sec.)

Designed floating life(20)

7~10 years

◆ Absorbent glass mat technology;

◆ Recognized by UL & CE;

◆ ABS container.







 

Constant Current Discharge Characteristics (A, 25)

F.V/TIME

5min

10min

15min

20min

30min

45min

60min

2h

3h

4h

5h

10h

20h

1.60V/cell

465

310

254

203

144

107

87.3

49.0

35.1

28.3

24.6

13.8

7.30

1.65V/cell

451

301

247

198

141

105

86.0

48.7

34.9

28.1

24.5

13.8

7.28

1.67V/cell

444

296

246

195

139

104

85.1

48.5

34.8

28.0

24.4

13.7

7.28

1.70V/cell

432

288

238

191

136

102

83.8

48.2

34.7

27.9

24.3

13.7

7.26

1.75V/cell

414

276

230

184

133

99

82.2

47.5

34.4

27.7

24.1

13.6

7.22

1.80V/cell

390

260

218

174

128

96

79.6

46.3

33.4

26.9

23.4

13.5

7.17

Constant Power Discharge Characteristics (Watt/cell, 25) 

F.V/TIME

5min

10min

15min

20min

30min

45min

60min

2h

3h

4h

5h

10h

20h

1.60V/cell

826

564

482

391

277

207

169

95.5

69.2

55.7

48.7

27.6

14.6

1.65V/cell

800

557

474

382

272

202

166

94.9

68.8

55.4

48.4

27.5

14.6

1.67V/cell

788

550

470

376

268

200

164

94.6

68.6

55.2

48.3

27.5

14.6

1.70V/cell

767

542

461

368

263

196

162

94.1

68.3

55.0

48.1

27.4

14.5

1.75V/cell

743

521

453

355

257

191

159

92.7

67.8

54.6

47.8

27.3

14.4

1.80V/cell

721

494

447

337

248

184

154

90.3

65.8

53.0

46.3

27.1

14.3

Note: The above characteristics data can be obtained within three charge/discharge cycles. 








International certifications:
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval

BS approval


Typical Applications: 

Alarm System
Cable Television
Communication Equipment
Control Equipment
Security System
Medical Equipment
UPS
Power Tools
Toys
Emergency Power System 




Product Categories : Network Power/Reserve Battery > High Rate Discharge Battery

Email to this supplier
  • *Subject:
  • *To:
    Ms. SALES
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*

Related Products List

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send