Overview
Product Attributes

Model No.LFP12155FT

BrandFirstpower

TypeLead-Acid Batteries

UsageUPS

Nominal Voltage12V

Discharge RateMedium Discharge Rate

ShapeSquare Battery

ElectrolyteAcid

InstallationFixed

RechargeableChargeable

UPS Battery FactorySolar Power Battery

EMERENCY Battery FactoryBack-up Battery

LFP1240L(12V, 40Ah, LONG LIFE)Sealed Lead Acid Battery

Supply Ability & Additional Information

Packaging Carton & pallet packaging

Productivity2000, 000kvah/ Year

TransportationOcean,Land

Place of Originchina

Supply Ability2000, 000kvah/ Year

Certificateiso,UL,CE

Payment TypeL/C,T/T,D/P

IncotermFOB,CFR,CIF

Packaging & Delivery
Selling Units:
Piece/Pieces
Package Type:
Carton & pallet packaging

LONG  LIFE LFP12155FT  BATTERY

The   LFP12155FT  BATTERY is desgined for general purpose and long life, focus on improving trickle life that base on FP series. Main features as follow:


  When it is used in safe surroundings, the battery is maintenance free, no need adding water and it can be recharged repeatedly.

ü   With isolated seal, it can be put in horizontal way, vertical way and side way, its safety and functions totally will not be affected.

ü   With special formula to manufacture lead calcium alloy as well as automatic progresses, gassing will be less.

ü   Long life, low self-discharge rate and high reliability.

ü   It has safety, low resistance so recharge is easy and energy output is more remarkable.

ü   Container material could be frame retardant ABS or PP with ranking UL 94V-0 by model.

ü   Standby use.

ü   High rate discharge construction.Rechargeable Cell Charger

ü   Deep discharge recoverability.

ü   Batteries are strictly tested by our patented computer charge/discharge system.

ü   ISO9001, 14001, OHSMS 18001 certified.

ü   UL recognized components under UL 1989 (file number MH14533).

ü   Complies with IATA/ICAO Special Provision A67 for air transport.

ü   Classified per MG Amendment 27 as a non-hazardous material for water transport.

ü   Recognized by DOT as "Dry charge" 49 CFR 171-189 for surface transport.

Battery_Series_Long_Life_s





International certifications:

  • ISO9001 approval, FN: Q3105105131
  • ISO14001 CTC04912E10302ROM
  • OHS MS18001 04912S10150ROM
  • UL approval, FN:MH28204
  • CE approval, FN:G2M20201-0102-E-16
  • KS approval, FN:KS C 8519
  • VDS approval
  • BS approval

General Features

  • Nonspillable
  • Sealed and Maintenance-free Operation
  • Front terminal,convenience for facilitate testing and servicing.  
  • High Quality and High Reliability
  • Exceptional Deep Discharge Recovery
  • Low Self-discharge
  • Long Service Life
  • Solid Copper Terminals
  • Tank-formed Plates
  • Computer-aided Design and Manufacturing
  • UL, CE, VdS Approved
 

Typical Applications

  • 1.UPS and EPS
    2.Emergency lightp
    3.Railway signal and aircraft signal system
    4.Marine and power stations
    5.Alarm and security system;
    6.Electronic apparatus and equipment
    7.Communication power supply, DC power supply


Specifications

Nominal Voltage

12 V

Capacity

(25)

10HR(10.8V) 

155Ah

5HR(10.5V)

135.5Ah

1HR(9.60V)

96Ah

Dimension

Length

551±3mm (21.69inch)

Width

110±2mm (4.33inch)

Height

287±2mm (11.30inch)

Total Height

287±2mm (11.30inch)

Approx. Weight

48.0kg (105.8lbs)±4%

Terminal type

T11

Internal resistance

(Fully charged, 25)

Approx. 4mΩ

Capacity affected by temperature (10HR)

40

102%

25

100%

0

85%

-15

65%

Self-discharge

(25)

3 month

Remaining Capacity: 91%

6 month

Remaining Capacity: 82%

12 month

Remaining Capacity: 65%

Nominal operating temperature

25±3(77℉±5℉)

Operating temperature range

Discharge

-15~50(5℉~122)

Charge

-10~50(14℉~122)

Storage

-20~50(-4℉~122)

Float charging voltage(25)

13.50 to 13.80V

Temperature compensation:

-18mV/

Cyclic charging voltage(25)

14.50 to 14.90V

Temperature compensation:

-30mV/

Maximum charging current

46.5A

Terminal material

Copper

Maximum discharge current

1200A(5 sec.)

Designed floating life(20)

15 years

◆ Absorbent glass mat technology;

◆ Recognized by UL & CE;

◆ ABS container.




 

Constant Current Discharge Characteristics (A, 25)

F.V/TIME

15min

30min

60min

2h

3h

4h

5h

6h

8h

10h

20h

9.60V

256

155

96

56.6

39.5

32.4

27.7

24.2

19.0

15.8

8.28

9.90V

250

152

95

56.3

39.3

32.2

27.5

24.0

18.9

15.7

8.27

10.2V

240

147

92

55.8

39.0

32.0

27.3

23.9

18.7

15.7

8.24

10.5V

232

144

90

55.0

38.8

31.8

27.1

23.7

18.6

15.6

8.19

10.8V

220

138

88

53.6

37.6

30.8

26.3

23.0

18.0

15.5

8.14

Constant Power Discharge Characteristics (Watt, 25) 

F.V/TIME

15min

30min

60min

2h

3h

4h

5h

6h

8h

10h

20h

9.60V

2808

1739

1096

656

465

381

327

286

225

188

99.4

9.90V

2741

1704

1079

652

462

379

325

284

224

188

99.2

10.2V

2640

1652

1052

646

459

376

323

282

223

187

98.9

10.5V

2550

1612

1031

636

456

374

321

280

221

186

98.3

10.8V

2415

1553

999

620

442

362

311

272

214

185

97.7

Note: The above characteristics data can be obtained within three charge/discharge cycles.




Product Categories : Network Power/Reserve Battery > Long Life Battery

Home > Products > Network Power/Reserve Battery > Long Life Battery > Strongest Rechargeable Aa Batteries
Email to this supplier
  • *Subject:
  • *To:
    Ms. SALES
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*

Related Products List

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send